Revision 0.00
25
Table 11: Local Address Space 1 (Bar 3)
Local Address
Contents Access
Description
10000000 SPI Command RW SPI controller command register, once command is written
operation begins
10000004 SPI Parameters RW There are four parameters, each one byte
- 0x04: Param0
- 0x05: Param1
- 0x06: Param2
- 0x07: Param3
10000008 SPI Status R SPI controller status register
- Bit 0: Operation complete
1000000C SPI Result R There are four results, each one byte
- 0x04: Result0
- 0x05: Result1
- 0x06: Result2
- 0x07: Result3
10000010 –
100000FC
Un addressable N/A N/A
10000100 –
100001FC
Dual port memory
RW 256 Bytes of for flash page storage
Implementation
Refer to the FreeForm/PCI-104 VHDL Reference Design Application Note for further information.