Connect Tech CPU Manual de Serviço Página 114

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 650
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 113
Configuration
CPU 317T: Technology Functions
4-38 A5E00251798-03
Stop time
The time set at "Stopping time" comes into effect when a moving axis is disabled
and Stop mode = 2 is set at the MC_Power parameter.
Velocity profile
The velocity profile defines the response of the axis during startup, deceleration,
and velocity changes.
The technology functions do not use the default value. Use input parameter Jerk to
edit the velocity profile.
You can choose the following profiles:
Trapezoidal
The trapezoidal profile is used for linear acceleration in positive and negative
direction of movement (jerk = 0).
Smooth
The profile shows a linear acceleration, the jerk profile is controllable
(jerk <> 0).
Vista de página 113
1 2 ... 109 110 111 112 113 114 115 116 117 118 119 ... 649 650

Comentários a estes Manuais

Sem comentários