Configuration
CPU 317T: Technology Functions
4-76 A5E00251798-03
4.6.3 Synchronization
Coupling to the control value during synchronization or sync off operations can be
defined differently, depending on the application.
This is defined by the:
Synchronization mode
Synchronization position
Value of the synchronization position
Synchronization criterion
the direction of synchronization (modulo axes only)
You can set the following sync modes in the "Dynamics" tab of the Synchronous
operation > Default dialog box:
Leading axis-related synchronization profile: Synchronization and sync off
based on control values
Time-related synchronization profile: Synchronization and sync off based on
dynamic values
Synchronization based on a leading axis-specific synchronization profile