Technology functions
CPU 317T: Technology Functions
A5E00251798-03
6-97
6.2.12 FB 437 MC_SetTorqueLimit - Enable / disable torque reduction
Purpose
The "MC_SetTorqueLimit" technology function enables/disables torque limiting.
Torque limiting is always disabled when the axis enable signal is reset.
Applicable to
Velocity axes
Positioning axes
Synchronization axes
Requirements
No MC_Stop command busy
The axis is enabled for velocity and position control
The torque reference for the axis must be set correctly, in order to maintain the
specified torque. The preset reference torque value is 3.2 N/m.
The relevant telegrams 101 to 105 are selected
The drive supports the "MC_MoveToEndPos" technology function
Overriding commands
MC_SetTorqueLimit
MC_Power (Enable = FALSE)
MC_SetTorqueLimit
(Cancellation relationships are shown in read direction)